INTEOS® M4 palmar plate, watershed version, with screws

Hand & Wrist · Distal Radius Fixation

INTEOS® Distal Radius System M4

Titanium palmar locking plates and Ø 2.5 mm screws for distal radius fracture fixation and corrective osteotomy close to the wrist joint. Four head widths and up to nine angular-stable head screws, with dorsal and distal ulna plates in the same system. Manufactured by Hofer Medical Solutions in Austria.

Manufactured by Hofer Medical Solutions (Austria) · Distributed in Cyprus by OrganoGEN Limited

2.0 mmPlate thickness
(standard, narrow, wide)
Up to 9Polyaxial, angular-stable
head screws
4Palmar head widths
(21 to 28 mm)
Ø 2.5 mmLocking and standard
screws
verifiedGESY-Covered (Selected Plates)publicCE-Marked Class IIbscienceVariable-Angle Lockingsupport_agentExclusive Cyprus Distributor

In One Paragraph

The INTEOS® Distal Radius System M4 is a titanium plate-and-screw system for distal radius fracture fixation and corrective osteotomy close to the joint, manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. It comprises palmar, dorsal and distal ulna plates. The M4 palmar plates take up to nine angular-stable head screws and use Ø 2.5 mm locking and standard screws. Hofer states that its INTEOS®Lock system allows angular variability of up to 70° with full angular stability. Plates and screws are CE-marked Class IIb under EU MDR 2017/745 (notified body 0483). OrganoGEN is the exclusive distributor of the Hofer Medical Solutions INTEOS® distal radius system in Cyprus. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation. Other plates are confirmed case by case with OrganoGEN.

Overview

The INTEOS® Distal Radius System M4 is Hofer Medical Solutions' current distal radius plate-and-screw system, which Hofer describes as multidirectional and angle-stable, built on the internal fixator principle. It is indicated for malposition or instability of a distal radius fracture at the typical site, with or without joint involvement, and for corrective osteotomy close to the joint for post-fracture malposition. The palmar plates use a standard flexor-side approach.

The M4 palmar plates are low-profile and made of titanium. The standard, narrow, wide and multihole plates are 2.0 mm thick, with four head widths from 21 mm (narrow) to 28 mm (wide), and take up to nine polyaxial, angular-stable epiphyseal screws. They use Ø 2.5 mm INTEOS® locking and standard screws with a ForceDRIVE T6 drive. Features include an oblong hole for primary variable fixation, a reduction window, a third screw row, direct styloid fixation and K-wire holes up to 1.2 mm. The shape-left (SL) and shape-right (SR) plates can each be used on either radius.

Hofer states that its INTEOS®Lock locking system gives angular variability of up to 70° with full angular stability. Hofer's instructions for use add that angular-stable locking is weaker with the screw angled than on axis. The system also includes XXL, watershed, Y, PI, osteotomy, rim, lunate facet and revision palmar plates, dorsal plates and a distal ulna plate. It is part of the Hofer Osteosynthesis range, used in internal osteosynthesis of the distal radius.

OrganoGEN is the exclusive distributor of the Hofer Medical Solutions INTEOS® distal radius system in Cyprus. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation. Other plates are confirmed case by case with OrganoGEN.

Indications & Contraindications

check_circleIndicated For

  • Malposition or instability of a distal radius fracture at the typical site (loco typico), with or without joint involvement
  • Corrective osteotomy close to the joint for malposition after a wrist fracture or after fracture healing
  • Distal ulna plate: malposition or instability of a distal ulna fracture without joint involvement (23-A1 fracture), and corrective osteotomy close to the joint after fracture or fracture healing

blockContraindicated For

  • Absolute: known or suspected sensitivity to the implant material
  • Absolute: application on the spine
  • Absolute: a mainly ulnar-dorsal, displaced articular fragment that cannot be adequately reduced and fixed from the flexor side (Barton fracture, AO B2)
  • Absolute: open wrist fracture grade 2 or 3 with wound contamination, without adequate intra-operative cleansing or soft-tissue cover
  • Relative: acute, chronic or local infection or inflammation, reduced blood flow to the area, reduced bone stability for secure implant fixation, or inadequate soft-tissue cover
  • Relative: open epiphyseal plates, obesity, or limited patient compliance with post-operative rehabilitation

Technical Specifications

ManufacturerHofer GmbH & Co KG (Hofer Medical Solutions), Fürstenfeld, Austria
Distributor in CyprusOrganoGEN Limited (exclusive)
Plate familiesPalmar (standard, narrow, wide, multihole, XXL, watershed, Y, PI, osteotomy, rim, lunate facet, revision), dorsal, distal ulna
Implant materialTitanium
Palmar head widthsNarrow 21 mm, standard 24.5 mm, multihole 26 mm, wide 28 mm
Plate thickness2.0 mm (standard, narrow, wide, multihole, watershed). XXL 3.2 mm. Revision 2.5 mm
Head screwsUp to 9 polyaxial, angular-stable epiphyseal screws
Screws (M4 palmar plates)INTEOS® 2.5 locking screws 6 to 44 mm and standard screws 6 to 32 mm, in 2 mm steps, Ø 2.5 mm, self-tapping
DrillØ 2.0 mm standard. Ø 1.8 mm for poor bone quality
DriveForceDRIVE T6
Locking systemINTEOS®Lock (Hofer: up to 70° with full angular stability)
RegulatoryCE-marked Class IIb under EU MDR 2017/745 (notified body 0483) for plates and screws. Instruments Class I or IIa
GESY status in CyprusCovered for distal radius fracture fixation with the standard, narrow, wide and XXL M4 palmar plates. Other plates case by case

GESY Coverage & Pricing in Cyprus

The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation. When they are implanted by a participating surgeon at a GESY-contracted hospital, the cost of the implants is included in the hospital reimbursement; patients are not billed separately. Other plates are confirmed case by case with OrganoGEN.

For self-pay or international patients, OrganoGEN provides hospital quotations on request. Request a quote.

Frequently asked questions

What is the INTEOS® Distal Radius System M4 indicated for?
For the distal radius plates, Hofer lists two indications: malposition or instability of a distal radius fracture at the typical site (loco typico), with or without joint involvement, and corrective osteotomy close to the joint for malposition after a wrist fracture or after it has healed. Hofer lists a mainly ulnar-dorsal, displaced articular fragment that cannot be adequately reduced and fixed from the flexor side (Barton fracture, AO B2) as an absolute contraindication.
Which plates does the INTEOS® Distal Radius System M4 include?
Palmar plates in four head widths (narrow 21 mm, standard 24.5 mm, multihole 26 mm, wide 28 mm), plus XXL, watershed, Y, PI, osteotomy, rim, lunate facet and revision palmar plates, dorsal plates and a distal ulna plate. The M4 palmar plates take INTEOS® 2.5 locking screws (6 to 44 mm) and standard screws (6 to 32 mm), both Ø 2.5 mm.
How does the INTEOS®Lock locking system work?
Hofer states that INTEOS®Lock gives angular variability of up to 70° with full angular stability, through the combination of the screw head and a pre-angulated threaded plate hole. Hofer's instructions for use note that angular-stable locking is less strong with the screw angled than on axis. Separately, Hofer describes the screw-to-screwdriver connection as "stick-fit": the screw is positively engaged with the screwdriver. That is screw retention, not part of the locking.
Is the INTEOS® Distal Radius System M4 CE-marked?
Yes. The plates and screws are CE-marked Class IIb under EU MDR 2017/745 (notified body 0483). The instruments are Class I or IIa.
Is the INTEOS® Distal Radius System M4 covered by GESY in Cyprus?
Yes, for selected plates. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation when implanted by a participating surgeon at a GESY-contracted hospital. Other plates are confirmed case by case with OrganoGEN. For self-pay or international patients, OrganoGEN provides hospital quotations on request.
Who manufactures the INTEOS® Distal Radius System M4?
Hofer GmbH & Co KG, trading as Hofer Medical Solutions, in Fürstenfeld, Austria. OrganoGEN is the exclusive distributor of the Hofer Medical Solutions INTEOS® distal radius system in Cyprus.
How does the INTEOS® Distal Radius System M4 relate to the Hofer Osteosynthesis range?
It is Hofer's distal radius system, one of the Hofer Medical Solutions product systems that OrganoGEN distributes in Cyprus. The wider Hofer locking-plate portfolio is on the Hofer Osteosynthesis page, and the operation itself is described under internal osteosynthesis.

More in Hand & Wrist

Other products OrganoGEN distributes in the Hand & Wrist category.

arrow_back
INTEOS® Distal Radius
Hand & Wrist · Distal Radius Fixation

INTEOS® Distal Radius System M4

Titanium palmar locking plates and Ø 2.5 mm screws for distal radius fracture fixation and corrective osteotomy close to the wrist joint. Four head widths and up to nine angular-stable head screws, with dorsal and distal ulna plates in the same system. Manufactured by Hofer Medical Solutions in Austria.

verifiedGESY-Covered (Selected Plates)publicCE-Marked Class IIbscienceVariable-Angle Lockingsupport_agentExclusive Cyprus Distributor
INTEOS® M4 palmar plate, watershed version, with screws
INTEOS® M4 palmar plates with locking and standard screws and the screwdriver
INTEOS® M4 palmar plate in situ on the distal radius, AP X-ray
Three INTEOS® M4 palmar plates with screws on transparent radius bone models
Side view of two INTEOS® M4 palmar plates with screws
INTEOS® M4 distal radius plates of several shapes, with screws
INTEOS® radius plates with screws

In One Paragraph

The INTEOS® Distal Radius System M4 is a titanium plate-and-screw system for distal radius fracture fixation and corrective osteotomy close to the joint, manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. It comprises palmar, dorsal and distal ulna plates. The M4 palmar plates take up to nine angular-stable head screws and use Ø 2.5 mm locking and standard screws. Hofer states that its INTEOS®Lock system allows angular variability of up to 70° with full angular stability. Plates and screws are CE-marked Class IIb under EU MDR 2017/745 (notified body 0483). OrganoGEN is the exclusive distributor of the Hofer Medical Solutions INTEOS® distal radius system in Cyprus. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation. Other plates are confirmed case by case with OrganoGEN.

Overview

Overview

The INTEOS® Distal Radius System M4 is Hofer Medical Solutions' current distal radius plate-and-screw system, which Hofer describes as multidirectional and angle-stable, built on the internal fixator principle. It is indicated for malposition or instability of a distal radius fracture at the typical site, with or without joint involvement, and for corrective osteotomy close to the joint for post-fracture malposition. The palmar plates use a standard flexor-side approach.

The M4 palmar plates are low-profile and made of titanium. The standard, narrow, wide and multihole plates are 2.0 mm thick, with four head widths from 21 mm (narrow) to 28 mm (wide), and take up to nine polyaxial, angular-stable epiphyseal screws. They use Ø 2.5 mm INTEOS® locking and standard screws with a ForceDRIVE T6 drive. Features include an oblong hole for primary variable fixation, a reduction window, a third screw row, direct styloid fixation and K-wire holes up to 1.2 mm. The shape-left (SL) and shape-right (SR) plates can each be used on either radius.

Clinical Use

Indications & Contraindications

check_circleIndicated for

  • Malposition or instability of a distal radius fracture at the typical site (loco typico), with or without joint involvement
  • Corrective osteotomy close to the joint for malposition after a wrist fracture or after fracture healing
  • Distal ulna plate: malposition or instability of a distal ulna fracture without joint involvement (23-A1 fracture), and corrective osteotomy close to the joint after fracture or fracture healing

cancelContraindicated

  • Absolute: known or suspected sensitivity to the implant material
  • Absolute: application on the spine
  • Absolute: a mainly ulnar-dorsal, displaced articular fragment that cannot be adequately reduced and fixed from the flexor side (Barton fracture, AO B2)
  • Absolute: open wrist fracture grade 2 or 3 with wound contamination, without adequate intra-operative cleansing or soft-tissue cover
  • Relative: acute, chronic or local infection or inflammation, reduced blood flow to the area, reduced bone stability for secure implant fixation, or inadequate soft-tissue cover
  • Relative: open epiphyseal plates, obesity, or limited patient compliance with post-operative rehabilitation
Technical

Technical Specifications

Manufacturer
Hofer GmbH & Co KG (Hofer Medical Solutions), Fürstenfeld, Austria
Distributor in Cyprus
OrganoGEN Limited (exclusive)
Plate families
Palmar (standard, narrow, wide, multihole, XXL, watershed, Y, PI, osteotomy, rim, lunate facet, revision), dorsal, distal ulna
Implant material
Titanium
Palmar head widths
Narrow 21 mm, standard 24.5 mm, multihole 26 mm, wide 28 mm
Plate thickness
2.0 mm (standard, narrow, wide, multihole, watershed). XXL 3.2 mm. Revision 2.5 mm
Head screws
Up to 9 polyaxial, angular-stable epiphyseal screws
Screws (M4 palmar plates)
INTEOS® 2.5 locking screws 6 to 44 mm and standard screws 6 to 32 mm, in 2 mm steps, Ø 2.5 mm, self-tapping
Drill
Ø 2.0 mm standard. Ø 1.8 mm for poor bone quality
Drive
ForceDRIVE T6
Locking system
INTEOS®Lock (Hofer: up to 70° with full angular stability)
Regulatory
CE-marked Class IIb under EU MDR 2017/745 (notified body 0483) for plates and screws. Instruments Class I or IIa
GESY status in Cyprus
Covered for distal radius fracture fixation with the standard, narrow, wide and XXL M4 palmar plates. Other plates case by case
GESY & Cost

GESY Coverage & Pricing in Cyprus

The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation. When they are implanted by a participating surgeon at a GESY-contracted hospital, the cost of the implants is included in the hospital reimbursement; patients are not billed separately. Other plates are confirmed case by case with OrganoGEN.

For self-pay or international patients, OrganoGEN provides hospital quotations on request. Request a quote.

FAQ

Frequently asked questions

What is the INTEOS® Distal Radius System M4 indicated for?
For the distal radius plates, Hofer lists two indications: malposition or instability of a distal radius fracture at the typical site (loco typico), with or without joint involvement, and corrective osteotomy close to the joint for malposition after a wrist fracture or after it has healed. Hofer lists a mainly ulnar-dorsal, displaced articular fragment that cannot be adequately reduced and fixed from the flexor side (Barton fracture, AO B2) as an absolute contraindication.
Which plates does the INTEOS® Distal Radius System M4 include?
Palmar plates in four head widths (narrow 21 mm, standard 24.5 mm, multihole 26 mm, wide 28 mm), plus XXL, watershed, Y, PI, osteotomy, rim, lunate facet and revision palmar plates, dorsal plates and a distal ulna plate. The M4 palmar plates take INTEOS® 2.5 locking screws (6 to 44 mm) and standard screws (6 to 32 mm), both Ø 2.5 mm.
How does the INTEOS®Lock locking system work?
Hofer states that INTEOS®Lock gives angular variability of up to 70° with full angular stability, through the combination of the screw head and a pre-angulated threaded plate hole. Hofer's instructions for use note that angular-stable locking is less strong with the screw angled than on axis. Separately, Hofer describes the screw-to-screwdriver connection as "stick-fit": the screw is positively engaged with the screwdriver. That is screw retention, not part of the locking.
Is the INTEOS® Distal Radius System M4 CE-marked?
Yes. The plates and screws are CE-marked Class IIb under EU MDR 2017/745 (notified body 0483). The instruments are Class I or IIa.
Is the INTEOS® Distal Radius System M4 covered by GESY in Cyprus?
Yes, for selected plates. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation when implanted by a participating surgeon at a GESY-contracted hospital. Other plates are confirmed case by case with OrganoGEN. For self-pay or international patients, OrganoGEN provides hospital quotations on request.
Who manufactures the INTEOS® Distal Radius System M4?
Hofer GmbH & Co KG, trading as Hofer Medical Solutions, in Fürstenfeld, Austria. OrganoGEN is the exclusive distributor of the Hofer Medical Solutions INTEOS® distal radius system in Cyprus.
How does the INTEOS® Distal Radius System M4 relate to the Hofer Osteosynthesis range?
It is Hofer's distal radius system, one of the Hofer Medical Solutions product systems that OrganoGEN distributes in Cyprus. The wider Hofer locking-plate portfolio is on the Hofer Osteosynthesis page, and the operation itself is described under internal osteosynthesis.