Hofer INTEOS superolateral clavicle plate on a bone model

Orthopaedics & Trauma · Locking Plates

Hofer Osteosynthesis Locking-Plate System

Anatomically contoured titanium locking plates with INTEOS®Lock polyaxial locking, covering the upper and lower extremity. Manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. GESY-covered across most standard internal-fixation indications in Cyprus.

Manufactured by Hofer Medical Solutions (Austria) · Distributed in Cyprus by OrganoGEN Limited

GESYCovered for most
standard fixation
TitaniumImplant material
±35°INTEOS®Lock polyaxial
locking range
8+Anatomical regions
covered
verifiedGESY-Covered (Most Indications)scienceINTEOS®Lock ±35°publicCE-Markedsupport_agentSurgical Support

In One Paragraph

Hofer Osteosynthesis is a comprehensive locking-plate system for upper and lower extremity fracture fixation, manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. Plates are titanium, anatomically pre-contoured, and use INTEOS®Lock low-profile polyaxial locking. Anatomical coverage spans clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula and distal tibia, plus hand and long-bone plating. CE-marked under EU MDR 2017/745. GESY-covered across most standard internal-fixation indications in Cyprus. Distributed by OrganoGEN.

Overview

Hofer Osteosynthesis is the locking-plate portfolio of Hofer Medical Solutions, an Austrian orthopaedic-trauma manufacturer headquartered in Fürstenfeld. The system supplies anatomically pre-contoured titanium locking plates and matching instrumentation for fracture fixation and reconstruction across the full upper and lower extremity.

Locking uses INTEOS®Lock, Hofer's polyaxial (variable-angle) locking interface. Hofer states that a spherical screw head and a threaded plate hole let a locking screw be angled by up to ±35° (70° total range) with full angular stability, and that the screw head sits with no or minimal protrusion; its instructions for use note that angular-stable locking is weaker with the screw angled than on axis. Hofer describes its locking screw technology as patented. On the XS minifragment plates for the hand, the INTEOS® Standard screw locks polyaxially and the INTEOS® Conic eXtreme screw gives angle-stable locking. StickFIT is a separate feature: the precision-made connection that holds the screw on the screwdriver tip during insertion.

Anatomical coverage spans clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula and distal tibia, plus hand and long-bone plating - eight or more pre-contoured plate families addressing the working list of trauma indications seen in Cypriot operating theatres.

In Cyprus, the Hofer Osteosynthesis portfolio is GESY-covered across most standard internal-fixation indications, reimbursed when implanted by a participating surgeon at a GESY-contracted hospital. OrganoGEN provides direct surgical support at every implantation.

Indications & Contraindications

check_circleIndicated For

  • Long-bone fractures of the upper and lower extremity requiring locking-plate osteosynthesis
  • Periarticular and articular fractures suitable for plate fixation (clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula, distal tibia)
  • Osteotomy fixation

blockContraindicated For

  • Absolute: possible or existing sensitivity to the material
  • Absolute: application on the spine
  • Relative: acute, chronic or local infection or inflammation, decreased blood flow to the affected area, reduced bone stability for correct implant fixation, or inadequate soft tissue coverage
  • Relative: open epiphyseal plates, obesity, or little or no patient compliance with post-operative rehabilitation recommendations
  • Relative: open soiled fractures that cannot be adequately cleansed

Technical Specifications

ManufacturerHofer Medical Solutions, Fürstenfeld, Austria
Distributor in CyprusOrganoGEN Limited
PortfolioAnatomical titanium locking plates, compression plates, cannulated screws, instrumentation
Locking technologyINTEOS®Lock polyaxial locking, up to ±35° (70° total range). XS hand minifragment plates: polyaxial (INTEOS® Standard screw) or angle-stable (INTEOS® Conic eXtreme screw)
Implant materialTitanium
Anatomical coverageClavicle, proximal humerus, elbow, distal radius / ulna, foot, fibula, distal tibia, plus hand and long-bone plating
RegulatoryCE-marked under EU MDR 2017/745
GESY status in CyprusCovered across most standard internal-fixation indications

GESY Coverage & Pricing in Cyprus

Hofer Osteosynthesis is GESY-covered in Cyprus across most standard internal-fixation indications when implanted by a participating surgeon at a GESY-contracted hospital. The cost of the device is included in the hospital reimbursement; patients are not billed separately. Other uses, including the OSTYS® Compression Screw 2.8 for hand or wrist use, are confirmed case by case with OrganoGEN.

For self-pay or international patients, OrganoGEN provides hospital quotations on request. Request a quote.

Frequently asked questions

Who manufactures Hofer Osteosynthesis?
Hofer Medical Solutions, headquartered in Fürstenfeld, Austria. OrganoGEN is the exclusive distributor in Cyprus.
What is INTEOS®Lock, and how does it differ from StickFIT?
INTEOS®Lock is Hofer's polyaxial (variable-angle) locking interface. Hofer states that a spherical screw head and a threaded plate hole let a locking screw be angled by up to ±35° (70° total range) with full angular stability, and describes its locking screw technology as patented. Hofer's instructions for use note that angular-stable locking is weaker with the screw angled than on axis. On the XS minifragment plates for the hand, the INTEOS® Standard screw locks polyaxially and the INTEOS® Conic eXtreme screw gives angle-stable locking. StickFIT is a separate feature: the precision-made connection that holds the screw on the screwdriver tip while it is inserted.
What anatomy does the Hofer system cover?
Eight or more anatomical regions: clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula and distal tibia, plus hand and long-bone plating. The plates are anatomically pre-contoured and offered in titanium.
Which Hofer systems are used in the hand and wrist?
Three Hofer systems have their own pages. The INTEOS® Distal Radius System M4 has palmar and dorsal plates for distal radius fractures, and a distal ulna plate. The XS-INTEOS® Minifragment System has plates and screws for fractures of the small bones of the hand. The OSTYS® Compression Screw 2.8 is a cannulated compression screw for small bones and small bone fragments. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation, and the minifragment system for metacarpal and phalangeal fractures; other plates and the OSTYS® 2.8 are confirmed case by case.
Is Hofer Osteosynthesis covered by GESY in Cyprus?
Yes, across most standard internal-fixation indications, when implanted by a participating surgeon at a GESY-contracted hospital. Other uses, including the OSTYS® Compression Screw 2.8 for hand or wrist use, are confirmed case by case with OrganoGEN.
Is Hofer Osteosynthesis CE-marked?
Yes. The Hofer portfolio is CE-marked under EU MDR 2017/745.
How does Hofer Osteosynthesis compare to other locking-plate systems?
Hofer's differentiator is INTEOS®Lock polyaxial locking (up to ±35°, 70° in total) combined with the breadth of anatomical pre-contouring. Pricing is provided on hospital quotation.
How can a Cyprus hospital obtain Hofer Osteosynthesis?
OrganoGEN supplies the device directly to GESY-contracted hospitals. Hospital procurement teams can request a quotation through the contact form or by email at info@organogenbiotech.com.

More in Orthopaedics & Trauma

Other products OrganoGEN distributes in the Orthopaedics & Trauma category.

arrow_back
Hofer Osteosynthesis
Orthopaedics & Trauma · Locking Plates

Hofer Osteosynthesis Locking-Plate System

Anatomically contoured titanium locking plates with INTEOS®Lock polyaxial locking, covering the upper and lower extremity. Manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. GESY-covered across most standard internal-fixation indications in Cyprus.

verifiedGESY-Covered (Most Indications)scienceINTEOS®Lock ±35°publicCE-Markedsupport_agentSurgical Support
Hofer INTEOS superolateral clavicle plate on a bone model
Hofer INTEOS superior clavicle plates
Hofer OSTYS cannulated screws
Hofer INTEOS proximal humerus plate with locking screws
Hofer INTEOS calcaneus plate with screws and guide
Hofer INTEOS olecranon plate on a bone model
Hofer INTEOS olecranon plate system
Hofer INTEOS M4 distal radius plates with locking screws
Hofer INTEOS proximal humerus plate, post-operative X-ray
Hofer INTEOS calcaneus plate, post-operative X-ray
Hofer INTEOS clavicle plate, post-operative X-ray
Hofer OSTYS cannulated screw range
Hofer OSTYS cannulated screw with drill guide
Hofer INTEOS fibula plate with screws and inserter
Hofer INTEOS fibula plate with its screw range
Hofer INTEOS distal humerus plate, intra-operative X-ray

In One Paragraph

Hofer Osteosynthesis is a comprehensive locking-plate system for upper and lower extremity fracture fixation, manufactured by Hofer Medical Solutions in Fürstenfeld, Austria. Plates are titanium, anatomically pre-contoured, and use INTEOS®Lock low-profile polyaxial locking. Anatomical coverage spans clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula and distal tibia, plus hand and long-bone plating. CE-marked under EU MDR 2017/745. GESY-covered across most standard internal-fixation indications in Cyprus. Distributed by OrganoGEN.

Overview

Overview

Hofer Osteosynthesis is the locking-plate portfolio of Hofer Medical Solutions, an Austrian orthopaedic-trauma manufacturer headquartered in Fürstenfeld. The system supplies anatomically pre-contoured titanium locking plates and matching instrumentation for fracture fixation and reconstruction across the full upper and lower extremity.

Locking uses INTEOS®Lock, Hofer's polyaxial (variable-angle) locking interface. Hofer states that a spherical screw head and a threaded plate hole let a locking screw be angled by up to ±35° (70° total range) with full angular stability, and that the screw head sits with no or minimal protrusion; its instructions for use note that angular-stable locking is weaker with the screw angled than on axis. Hofer describes its locking screw technology as patented. On the XS minifragment plates for the hand, the INTEOS® Standard screw locks polyaxially and the INTEOS® Conic eXtreme screw gives angle-stable locking. StickFIT is a separate feature: the precision-made connection that holds the screw on the screwdriver tip during insertion.

Clinical Use

Indications & Contraindications

check_circleIndicated for

  • Long-bone fractures of the upper and lower extremity requiring locking-plate osteosynthesis
  • Periarticular and articular fractures suitable for plate fixation (clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula, distal tibia)
  • Osteotomy fixation

cancelContraindicated

  • Absolute: possible or existing sensitivity to the material
  • Absolute: application on the spine
  • Relative: acute, chronic or local infection or inflammation, decreased blood flow to the affected area, reduced bone stability for correct implant fixation, or inadequate soft tissue coverage
  • Relative: open epiphyseal plates, obesity, or little or no patient compliance with post-operative rehabilitation recommendations
  • Relative: open soiled fractures that cannot be adequately cleansed
Technical

Technical Specifications

Manufacturer
Hofer Medical Solutions, Fürstenfeld, Austria
Distributor in Cyprus
OrganoGEN Limited
Portfolio
Anatomical titanium locking plates, compression plates, cannulated screws, instrumentation
Locking technology
INTEOS®Lock polyaxial locking, up to ±35° (70° total range). XS hand minifragment plates: polyaxial (INTEOS® Standard screw) or angle-stable (INTEOS® Conic eXtreme screw)
Implant material
Titanium
Anatomical coverage
Clavicle, proximal humerus, elbow, distal radius / ulna, foot, fibula, distal tibia, plus hand and long-bone plating
Regulatory
CE-marked under EU MDR 2017/745
GESY status in Cyprus
Covered across most standard internal-fixation indications
GESY & Cost

GESY Coverage & Pricing in Cyprus

Hofer Osteosynthesis is GESY-covered in Cyprus across most standard internal-fixation indications when implanted by a participating surgeon at a GESY-contracted hospital. The cost of the device is included in the hospital reimbursement; patients are not billed separately. Other uses, including the OSTYS® Compression Screw 2.8 for hand or wrist use, are confirmed case by case with OrganoGEN.

For self-pay or international patients, OrganoGEN provides hospital quotations on request. Request a quote.

FAQ

Frequently asked questions

Who manufactures Hofer Osteosynthesis?
Hofer Medical Solutions, headquartered in Fürstenfeld, Austria. OrganoGEN is the exclusive distributor in Cyprus.
What is INTEOS®Lock, and how does it differ from StickFIT?
INTEOS®Lock is Hofer's polyaxial (variable-angle) locking interface. Hofer states that a spherical screw head and a threaded plate hole let a locking screw be angled by up to ±35° (70° total range) with full angular stability, and describes its locking screw technology as patented. Hofer's instructions for use note that angular-stable locking is weaker with the screw angled than on axis. On the XS minifragment plates for the hand, the INTEOS® Standard screw locks polyaxially and the INTEOS® Conic eXtreme screw gives angle-stable locking. StickFIT is a separate feature: the precision-made connection that holds the screw on the screwdriver tip while it is inserted.
What anatomy does the Hofer system cover?
Eight or more anatomical regions: clavicle, proximal humerus, elbow, distal radius and ulna, foot, fibula and distal tibia, plus hand and long-bone plating. The plates are anatomically pre-contoured and offered in titanium.
Which Hofer systems are used in the hand and wrist?
Three Hofer systems have their own pages. The INTEOS® Distal Radius System M4 has palmar and dorsal plates for distal radius fractures, and a distal ulna plate. The XS-INTEOS® Minifragment System has plates and screws for fractures of the small bones of the hand. The OSTYS® Compression Screw 2.8 is a cannulated compression screw for small bones and small bone fragments. The standard, narrow, wide and XXL M4 palmar plates are GESY-covered for distal radius fracture fixation, and the minifragment system for metacarpal and phalangeal fractures; other plates and the OSTYS® 2.8 are confirmed case by case.
Is Hofer Osteosynthesis covered by GESY in Cyprus?
Yes, across most standard internal-fixation indications, when implanted by a participating surgeon at a GESY-contracted hospital. Other uses, including the OSTYS® Compression Screw 2.8 for hand or wrist use, are confirmed case by case with OrganoGEN.
Is Hofer Osteosynthesis CE-marked?
Yes. The Hofer portfolio is CE-marked under EU MDR 2017/745.
How does Hofer Osteosynthesis compare to other locking-plate systems?
Hofer's differentiator is INTEOS®Lock polyaxial locking (up to ±35°, 70° in total) combined with the breadth of anatomical pre-contouring. Pricing is provided on hospital quotation.
How can a Cyprus hospital obtain Hofer Osteosynthesis?
OrganoGEN supplies the device directly to GESY-contracted hospitals. Hospital procurement teams can request a quotation through the contact form or by email at info@organogenbiotech.com.
More in Orthopaedics & Trauma

Related products